SIS3153 Ethernet SFP reset issue serial numbers16-39

The SIS3153 Ethernet to VME interfaces with serial numbers in the range from 16 to 39 have a some 10% probability reset issue at power up. Please have trained personel remove resistor R200A to remedy the erroneous pulldown. USB3.0 operation … Continue reading